Electrical calculators

Load and power, wire and voltage drop, motors and protection, 24V control power, heat, lighting, backup, and raceway, each with visible math.

Calculator

Dwelling Service Load Calculator

Residential service size by NEC 220.82: general load with demand plus larger HVAC. 5 inputs, 4 outputs with grouped results.

Outputs: General load (VA) · Service load (VA) · Service current

Open calculator

Calculator

Battery Charger Sizer

Charger amps from amp-hours, recharge window, and concurrent load. 4 inputs, 2 outputs with grouped results.

Outputs: Required charger current · Standard charger size

Open calculator

Calculator

Cable Tray Fill Calculator

Tray fill per NEC 392: allowable area, cable area used, and the fill verdict. 5 inputs, 4 outputs with grouped results.

Outputs: Allowable fill area · Cable area used · Fill used

Open calculator

Calculator

Arc Flash Incident Energy Screening

First-pass incident energy and flash boundary from fault current, clearing time, and distance. 5 inputs, 3 outputs with grouped results.

Outputs: Incident energy · Flash boundary · Planning PPE category

Open calculator

Calculator

Harmonic Neutral Sizer

Neutral ampacity for nonlinear loads with the 200% neutral call. 3 inputs, 3 outputs with grouped results.

Outputs: Calculated neutral current · Required neutral ampacity · Use 200% neutral (1=yes)

Open calculator

Calculator

VFD Input Current and Line Reactor Check

Drive input current from motor HP with efficiency, feeder at 125%, and the reactor call. 5 inputs, 3 outputs with grouped results.

Outputs: Drive input current · Feeder at 125% · Add line reactor (1=yes)

Open calculator

Calculator

Feeder Tap Rule Checker

NEC 240.21 tap screening: 10-ft and 25-ft rules from length, size ratio, and termination OCPD. 5 inputs, 3 outputs with grouped results.

Outputs: Tap-to-feeder ratio · Meets 10-ft rule (1=yes) · Meets 25-ft rule (1=yes)

Open calculator

Calculator

Enclosure Ventilation Fan Sizer

Cooling airflow for control panels: CFM from internal watts and allowed rise, with filtered-fan derate. 4 inputs, 3 outputs with grouped results.

Outputs: Base airflow · Required with filter · Needs air conditioner (1=yes)

Open calculator

Calculator

Control Transformer VA Sizer

Control power transformer VA per NEC 450: inrush plus sealed burden stepped to a standard CPT size. 5 inputs, 4 outputs with grouped results.

Outputs: Required VA · Standard CPT size · Primary current

Open calculator