Calculators

Raceway & Equipment calculators

Raceway and equipment: conduit fill, ampacity, fault current, transformers, and box fill.

Calculator

Arc Flash Incident Energy Screening

First-pass incident energy and flash boundary from fault current, clearing time, and distance. 5 inputs, 3 outputs with grouped results.

Outputs: Incident energy · Flash boundary · Planning PPE category

Open calculator

Calculator

Cable Tray Fill Calculator

Tray fill per NEC 392: allowable area, cable area used, and the fill verdict. 5 inputs, 4 outputs with grouped results.

Outputs: Allowable fill area · Cable area used · Fill used

Open calculator

Calculator

Conduit Fill Calculator

NEC Chapter 9 fill with wire-area picker, conduit picker, derating hint and spare verdict. 4 inputs, 4 outputs with grouped results.

Outputs: Raceway fill · NEC limit · Fill compliant (1=yes)

Open calculator

Calculator

Electrical Box Fill Calculator

NEC 314.16 fill from gauge-based allowance, conductors, devices, grounds, clamps, with verdict. 6 inputs, 4 outputs with grouped results.

Outputs: Conductor units · Fill used · Remaining

Open calculator

Calculator

Fault Current Calculator

Infinite-bus fault current with impedance picker, kA result, AIC verdict and common breaker ratings. 4 inputs, 4 outputs with grouped results.

Outputs: Available fault current · In kilo-amps · AIC margin

Open calculator

Calculator

Feeder Tap Rule Checker

NEC 240.21 tap screening: 10-ft and 25-ft rules from length, size ratio, and termination OCPD. 5 inputs, 3 outputs with grouped results.

Outputs: Tap-to-feeder ratio · Meets 10-ft rule (1=yes) · Meets 25-ft rule (1=yes)

Open calculator

Calculator

Panel SCCR Rating Check

Short-circuit current rating screening per NEC 409: weakest-link rating, series-tested combinations, and the available-fault verdict. 7 inputs, 5 outputs with grouped results.

Outputs: Panel SCCR · Weakest-link rating · SCCR margin

Open calculator

Calculator

Pull Box Sizer

Minimum length per NEC 314.28 for straight and angle pulls. 3 inputs, 1 output.

Outputs: Minimum box length

Open calculator

Calculator

Transformer Sizing Calculator

FLA both sides, 125% protection hints each side and standard primary OCPD. 3 inputs, 4 outputs with grouped results.

Outputs: Primary FLA · Secondary FLA · Primary OCPD

Open calculator

Calculator

Wire Ampacity Calculator

Dataset ampacity with temperature-rating picker, bundling derate, continuous limit and gauge verdict. 4 inputs, 3 outputs with grouped results.

Outputs: Table ampacity · After bundling · Max continuous load

Open calculator

Calculator

Wireway Fill Calculator

Fill at 20% of cross-section per NEC 376.22 with verdict. 3 inputs, 3 outputs.

Outputs: Allowable fill (sq in) · Fill used · Wireway adequate (1=yes)

Open calculator